Match the Right Kasco Control Panel to Your Fountain, Aerator, Circulator, or De-Icer

Every Kasco control panel is a UL- and CSA-listed, rain-proof enclosure that handles GFCI protection, daily run-time scheduling, and (on most models) lighting control for one Kasco fountain, aerator, circulator, or de-icer. Wiring a Kasco unit straight to a breaker works, but a control panel is what lets you run the unit on a daily schedule, dim the lights at the right time of night, and trip the GFCI safely when something goes wrong instead of damaging the motor.

Picking the right panel comes down to two things: which unit you're running, and whether you want a built-in lighting outlet. The C-10 and C-20 are dedicated thermostats for the De-Icer. The C-25 is the smallest fountain/aerator/circulator panel and the one most 120V owners need. The C-85, C-95, C-220, and C-230 cover bigger 240V units (the C-85 and C-95 include a lighting outlet; the C-220 and C-230 do not). The CF-3075 is the three-phase panel that fits the 7.5 HP J Series. Each panel ships with a 10% manufacturer restocking fee on returns.

One Kasco control panel per Kasco fountain, aerator, circulator, or de-icer. UL and CSA listed, rain-proof, GFCI-protected, 24-hour timer on every model. C-85, C-95, and CF-3075 also include a separate lighting outlet and a second timer for the lights.

C-10 and C-20 are thermostats for the De-Icer. C-25 is the 120V fountain/aerator/circulator panel. C-85/C-95 (with lighting) or C-220/C-230 (without lighting) cover 240V units. CF-3075 is the three-phase 7.5 HP J Series panel.

Free shipping on every Kasco Control Panel. Call (470) 354-1969 and we will confirm the right panel for your unit before you order.

Which Panel Do I Need

  • I own a Kasco De-Icer - pick C-10 for a simple air-temp thermostat, or C-20 if you want time-of-day scheduling layered on top of the temperature trigger.
  • I own a 120V Kasco fountain, AquatiClear, or Surface Aerator (1/2 to 1 HP) - C-25. Includes a photocell outlet for optional WaterGlow lighting.
  • I own a 240V Kasco fountain or surface aerator (3/4 to 2 HP) - C-85 if you want a built-in lighting outlet with a second timer; C-220 if you don't.
  • I own a 240V Kasco fountain or surface aerator (3 to 5 HP) - C-95 with lighting outlet, or C-230 without.
  • I own a 240V 7.5 HP J Series fountain (three-phase) - CF-3075. Dual 24-hour timers (unit + lights).
  • Still not sure? Call (470) 354-1969 with your unit's model number and we will match it to the right panel.

Control Panel Comparison

Panel Voltage / Phase Fits Features
C-10 120V / 1 phase De-Icer Air-temperature thermostat, 0-80°F operating range. Includes 8 ft cord.
C-20 120V / 1 phase De-Icer Time + temperature controller, 0-40°F operating range. Includes 3 ft cord.
C-25 120V / 1 phase 120V 1/2 - 1 HP Fountains, AquatiClear, Surface Aerators 24-hour timer, GFCI protection, photocell outlet for optional lighting.
C-85 208-240V / 1 phase 240V 3/4 - 1 HP AquatiClear; 240V 3/4 - 2 HP Fountains and Surface Aerators GFCB protection, 24-hour timer, surge protector, 120V GFI-protected lighting outlet, rain-proof enclosure. Two timers (unit + lights).
C-95 208-240V / 1 phase 240V 3 - 5 HP Fountains and Surface Aerators GFCB protection, 24-hour timer, surge protector, 120V GFI-protected lighting outlet, rain-proof enclosure. Two timers (unit + lights).
C-220 208-240V / 1 phase 240V 3/4 - 1 HP AquatiClear; 240V 3/4 - 2 HP Surface Aerators GFCB protection, 24-hour timer, surge protector. No lighting outlet.
C-230 208-240V / 1 phase 240V 3 - 5 HP Surface Aerators GFCB protection, 24-hour timer, surge protector. No lighting outlet.
CF-3075 208-240V / 3 phase 240V 7.5 HP J Series Fountain (three-phase) Dual 24-hour timers (unit + lights), GFCI protected. Three-phase only.
Each Kasco panel controls one unit. Do not add cord to a Kasco unit - factory-attached cord up to 500 ft is available at order time. Adding cord voids the warranty and ETL approval. Call (470) 354-1969 with sizing questions.

Key Features Across the Lineup

  • UL and CSA Listed: Every Kasco panel is approved and listed to the strictest UL and CSA safety standards. The whole motor + cord + panel package is ETL listed.
  • GFCI Protection: All panels except the De-Icer thermostats include human-rated GFCI protection. Test GFCI monthly per the instructions in the manual.
  • 24-Hour Timer Dial: Every fountain/aerator/circulator panel includes a 24-hour timer dial so you can program when the unit runs each day. Panels with a lighting outlet include a second separate timer just for the lights.
  • Photocell or Timer Lighting Control: The C-25 uses a photocell to turn the lights on at dusk. The C-85, C-95, and CF-3075 use a separate 24-hour timer for the lighting outlet. C-220 and C-230 do not include a lighting outlet.
  • Rain-Proof Enclosure: Panels are designed for outdoor mounting. NEMA-rated rain-proof enclosure on every C-25 and larger model.
  • Cord-Length Warning: Do not splice additional cord onto a Kasco unit. Kasco factory-attaches cord up to 500 ft at order time. Adding cord after the fact voids the warranty, voids ETL approval, and causes nuisance GFCI tripping.
Overview

Match the Right Kasco Control Panel to Your Fountain, Aerator, Circulator, or De-Icer

Every Kasco control panel is a UL- and CSA-listed, rain-proof enclosure that handles GFCI protection, daily run-time scheduling, and (on most models) lighting control for one Kasco fountain, aerator, circulator, or de-icer. Wiring a Kasco unit straight to a breaker works, but a control panel is what lets you run the unit on a daily schedule, dim the lights at the right time of night, and trip the GFCI safely when something goes wrong instead of damaging the motor.

Picking the right panel comes down to two things: which unit you're running, and whether you want a built-in lighting outlet. The C-10 and C-20 are dedicated thermostats for the De-Icer. The C-25 is the smallest fountain/aerator/circulator panel and the one most 120V owners need. The C-85, C-95, C-220, and C-230 cover bigger 240V units (the C-85 and C-95 include a lighting outlet; the C-220 and C-230 do not). The CF-3075 is the three-phase panel that fits the 7.5 HP J Series. Each panel ships with a 10% manufacturer restocking fee on returns.

One Kasco control panel per Kasco fountain, aerator, circulator, or de-icer. UL and CSA listed, rain-proof, GFCI-protected, 24-hour timer on every model. C-85, C-95, and CF-3075 also include a separate lighting outlet and a second timer for the lights.

C-10 and C-20 are thermostats for the De-Icer. C-25 is the 120V fountain/aerator/circulator panel. C-85/C-95 (with lighting) or C-220/C-230 (without lighting) cover 240V units. CF-3075 is the three-phase 7.5 HP J Series panel.

Free shipping on every Kasco Control Panel. Call (470) 354-1969 and we will confirm the right panel for your unit before you order.

Which Panel Do I Need

  • I own a Kasco De-Icer - pick C-10 for a simple air-temp thermostat, or C-20 if you want time-of-day scheduling layered on top of the temperature trigger.
  • I own a 120V Kasco fountain, AquatiClear, or Surface Aerator (1/2 to 1 HP) - C-25. Includes a photocell outlet for optional WaterGlow lighting.
  • I own a 240V Kasco fountain or surface aerator (3/4 to 2 HP) - C-85 if you want a built-in lighting outlet with a second timer; C-220 if you don't.
  • I own a 240V Kasco fountain or surface aerator (3 to 5 HP) - C-95 with lighting outlet, or C-230 without.
  • I own a 240V 7.5 HP J Series fountain (three-phase) - CF-3075. Dual 24-hour timers (unit + lights).
  • Still not sure? Call (470) 354-1969 with your unit's model number and we will match it to the right panel.

Control Panel Comparison

Panel Voltage / Phase Fits Features
C-10 120V / 1 phase De-Icer Air-temperature thermostat, 0-80°F operating range. Includes 8 ft cord.
C-20 120V / 1 phase De-Icer Time + temperature controller, 0-40°F operating range. Includes 3 ft cord.
C-25 120V / 1 phase 120V 1/2 - 1 HP Fountains, AquatiClear, Surface Aerators 24-hour timer, GFCI protection, photocell outlet for optional lighting.
C-85 208-240V / 1 phase 240V 3/4 - 1 HP AquatiClear; 240V 3/4 - 2 HP Fountains and Surface Aerators GFCB protection, 24-hour timer, surge protector, 120V GFI-protected lighting outlet, rain-proof enclosure. Two timers (unit + lights).
C-95 208-240V / 1 phase 240V 3 - 5 HP Fountains and Surface Aerators GFCB protection, 24-hour timer, surge protector, 120V GFI-protected lighting outlet, rain-proof enclosure. Two timers (unit + lights).
C-220 208-240V / 1 phase 240V 3/4 - 1 HP AquatiClear; 240V 3/4 - 2 HP Surface Aerators GFCB protection, 24-hour timer, surge protector. No lighting outlet.
C-230 208-240V / 1 phase 240V 3 - 5 HP Surface Aerators GFCB protection, 24-hour timer, surge protector. No lighting outlet.
CF-3075 208-240V / 3 phase 240V 7.5 HP J Series Fountain (three-phase) Dual 24-hour timers (unit + lights), GFCI protected. Three-phase only.
Each Kasco panel controls one unit. Do not add cord to a Kasco unit - factory-attached cord up to 500 ft is available at order time. Adding cord voids the warranty and ETL approval. Call (470) 354-1969 with sizing questions.

Key Features Across the Lineup

  • UL and CSA Listed: Every Kasco panel is approved and listed to the strictest UL and CSA safety standards. The whole motor + cord + panel package is ETL listed.
  • GFCI Protection: All panels except the De-Icer thermostats include human-rated GFCI protection. Test GFCI monthly per the instructions in the manual.
  • 24-Hour Timer Dial: Every fountain/aerator/circulator panel includes a 24-hour timer dial so you can program when the unit runs each day. Panels with a lighting outlet include a second separate timer just for the lights.
  • Photocell or Timer Lighting Control: The C-25 uses a photocell to turn the lights on at dusk. The C-85, C-95, and CF-3075 use a separate 24-hour timer for the lighting outlet. C-220 and C-230 do not include a lighting outlet.
  • Rain-Proof Enclosure: Panels are designed for outdoor mounting. NEMA-rated rain-proof enclosure on every C-25 and larger model.
  • Cord-Length Warning: Do not splice additional cord onto a Kasco unit. Kasco factory-attaches cord up to 500 ft at order time. Adding cord after the fact voids the warranty, voids ETL approval, and causes nuisance GFCI tripping.
Shipping/Returns

Shipping

  • Order confirmation is emailed after checkout.
  • Orders typically process within 1 to 2 business days.
  • Delivery times may vary depending on the product, shipping method, and delivery location.
  • A shipping confirmation with tracking details will be sent once your order ships.
  • Any damage or shortage claims must be reported within 24 hours of delivery. Please keep the original packaging until the claim is resolved.

Returns

  • Eligible merchandise may be returned within 30 days of purchase with prior return authorization.
  • All returns require an RA Number before the item is sent back.
  • Returned items must be in their original packaging and in saleable condition.
  • Non-warranty returns may be subject to a 15% restocking fee, and original shipping charges are non-refundable.
  • Warranty returns require authorization, the original sales receipt, and an explanation of the product issue.

Questions? Contact support@propondsupply.com or call (470) 354-1969.

Warranty

Warranty

  • Kasco Marine products are warranted to be free from defects in material and workmanship under normal use and service.
  • 2-year warranty: 1/2, 3/4, and 1HP Surface Aerators, J Series fountains, VFX fountains, AquatiClear™ Circulators, all 50Hz fountain, aerator, de-icer, and circulator models, LEDC11 Composite LED Light Kits, RGB LED Light Kits, Home Series cabinet and TeichAire compressor, and HydraForce™ Lift Station Agitators.
  • 3-year warranty: 1/2, 3/4, and 1HP De-icers, 2, 3, and 5HP VFX and Surface Aerator models, 2HP J Series models, LEDS19 Stainless Steel Light Kits, RGBW18 LED Light Kits, W25 LED Light Kits, CertiSafe™ Tank Mixers, and RobustAire™ TeichAire Compressors.
  • 5-year warranty: 3, 5, and 7.5HP J Series fountains and RGBW LED Light Kits.
  • 15-year warranty: SureSink™ Weighted Tubing for RobustAire™ and Home Series Diffused Aeration Systems.
  • Lifetime warranty: Diffuser assemblies for RobustAire™ and Home Series Diffused Aeration Systems, RobustAire™ Post Mount Cabinets, and RobustAire™ Small, Medium, and Large Cabinets with patented AireGuard Cabinet Technology.
  • Control panels are included in the warranty when applicable to the covered product.
  • Ropes, power cords, and propellers are excluded from standard defect coverage.
  • Customers should register their product with Kasco Marine for warranty purposes after purchase.
  • Warranty coverage may be void if the equipment is not properly maintained according to the owner’s manual, altered from its original condition, used without the required GFI-protected circuit or Kasco control panel, or damaged by unauthorized tampering.
  • Units under warranty may be sent to a Kasco authorized repair center for evaluation and repair, and all units must include the required Repair Contact Form.
  • Only complete motor assemblies will be accepted for warranty repair, and the power cord and all other original components must be returned with the motor as originally assembled.
  • Kasco Marine will return units repaired under warranty at their expense by ground freight within the continental United States, while expedited return shipping is the customer’s responsibility.

Questions? Contact support@propondsupply.com or call (470) 354-1969.

★Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
NO SALES TAX

Orders outside Georgia are 100% sales tax-free

Give us a call

Free shipping on every order

Give us a call

Our team is available from 8 AM to 8 PM EST at (470) 354-1969

BEST PRICE GUARANTEE

If you find the same item for less, we’ll match it.

Overview

Match the Right Kasco Control Panel to Your Fountain, Aerator, Circulator, or De-Icer

Every Kasco control panel is a UL- and CSA-listed, rain-proof enclosure that handles GFCI protection, daily run-time scheduling, and (on most models) lighting control for one Kasco fountain, aerator, circulator, or de-icer. Wiring a Kasco unit straight to a breaker works, but a control panel is what lets you run the unit on a daily schedule, dim the lights at the right time of night, and trip the GFCI safely when something goes wrong instead of damaging the motor.

Picking the right panel comes down to two things: which unit you're running, and whether you want a built-in lighting outlet. The C-10 and C-20 are dedicated thermostats for the De-Icer. The C-25 is the smallest fountain/aerator/circulator panel and the one most 120V owners need. The C-85, C-95, C-220, and C-230 cover bigger 240V units (the C-85 and C-95 include a lighting outlet; the C-220 and C-230 do not). The CF-3075 is the three-phase panel that fits the 7.5 HP J Series. Each panel ships with a 10% manufacturer restocking fee on returns.

One Kasco control panel per Kasco fountain, aerator, circulator, or de-icer. UL and CSA listed, rain-proof, GFCI-protected, 24-hour timer on every model. C-85, C-95, and CF-3075 also include a separate lighting outlet and a second timer for the lights.

C-10 and C-20 are thermostats for the De-Icer. C-25 is the 120V fountain/aerator/circulator panel. C-85/C-95 (with lighting) or C-220/C-230 (without lighting) cover 240V units. CF-3075 is the three-phase 7.5 HP J Series panel.

Free shipping on every Kasco Control Panel. Call (470) 354-1969 and we will confirm the right panel for your unit before you order.

Which Panel Do I Need

  • I own a Kasco De-Icer - pick C-10 for a simple air-temp thermostat, or C-20 if you want time-of-day scheduling layered on top of the temperature trigger.
  • I own a 120V Kasco fountain, AquatiClear, or Surface Aerator (1/2 to 1 HP) - C-25. Includes a photocell outlet for optional WaterGlow lighting.
  • I own a 240V Kasco fountain or surface aerator (3/4 to 2 HP) - C-85 if you want a built-in lighting outlet with a second timer; C-220 if you don't.
  • I own a 240V Kasco fountain or surface aerator (3 to 5 HP) - C-95 with lighting outlet, or C-230 without.
  • I own a 240V 7.5 HP J Series fountain (three-phase) - CF-3075. Dual 24-hour timers (unit + lights).
  • Still not sure? Call (470) 354-1969 with your unit's model number and we will match it to the right panel.

Control Panel Comparison

Panel Voltage / Phase Fits Features
C-10 120V / 1 phase De-Icer Air-temperature thermostat, 0-80°F operating range. Includes 8 ft cord.
C-20 120V / 1 phase De-Icer Time + temperature controller, 0-40°F operating range. Includes 3 ft cord.
C-25 120V / 1 phase 120V 1/2 - 1 HP Fountains, AquatiClear, Surface Aerators 24-hour timer, GFCI protection, photocell outlet for optional lighting.
C-85 208-240V / 1 phase 240V 3/4 - 1 HP AquatiClear; 240V 3/4 - 2 HP Fountains and Surface Aerators GFCB protection, 24-hour timer, surge protector, 120V GFI-protected lighting outlet, rain-proof enclosure. Two timers (unit + lights).
C-95 208-240V / 1 phase 240V 3 - 5 HP Fountains and Surface Aerators GFCB protection, 24-hour timer, surge protector, 120V GFI-protected lighting outlet, rain-proof enclosure. Two timers (unit + lights).
C-220 208-240V / 1 phase 240V 3/4 - 1 HP AquatiClear; 240V 3/4 - 2 HP Surface Aerators GFCB protection, 24-hour timer, surge protector. No lighting outlet.
C-230 208-240V / 1 phase 240V 3 - 5 HP Surface Aerators GFCB protection, 24-hour timer, surge protector. No lighting outlet.
CF-3075 208-240V / 3 phase 240V 7.5 HP J Series Fountain (three-phase) Dual 24-hour timers (unit + lights), GFCI protected. Three-phase only.
Each Kasco panel controls one unit. Do not add cord to a Kasco unit - factory-attached cord up to 500 ft is available at order time. Adding cord voids the warranty and ETL approval. Call (470) 354-1969 with sizing questions.

Key Features Across the Lineup

  • UL and CSA Listed: Every Kasco panel is approved and listed to the strictest UL and CSA safety standards. The whole motor + cord + panel package is ETL listed.
  • GFCI Protection: All panels except the De-Icer thermostats include human-rated GFCI protection. Test GFCI monthly per the instructions in the manual.
  • 24-Hour Timer Dial: Every fountain/aerator/circulator panel includes a 24-hour timer dial so you can program when the unit runs each day. Panels with a lighting outlet include a second separate timer just for the lights.
  • Photocell or Timer Lighting Control: The C-25 uses a photocell to turn the lights on at dusk. The C-85, C-95, and CF-3075 use a separate 24-hour timer for the lighting outlet. C-220 and C-230 do not include a lighting outlet.
  • Rain-Proof Enclosure: Panels are designed for outdoor mounting. NEMA-rated rain-proof enclosure on every C-25 and larger model.
  • Cord-Length Warning: Do not splice additional cord onto a Kasco unit. Kasco factory-attaches cord up to 500 ft at order time. Adding cord after the fact voids the warranty, voids ETL approval, and causes nuisance GFCI tripping.
Shipping/Returns

Shipping

  • Order confirmation is emailed after checkout.
  • Orders typically process within 1 to 2 business days.
  • Delivery times may vary depending on the product, shipping method, and delivery location.
  • A shipping confirmation with tracking details will be sent once your order ships.
  • Any damage or shortage claims must be reported within 24 hours of delivery. Please keep the original packaging until the claim is resolved.

Returns

  • Eligible merchandise may be returned within 30 days of purchase with prior return authorization.
  • All returns require an RA Number before the item is sent back.
  • Returned items must be in their original packaging and in saleable condition.
  • Non-warranty returns may be subject to a 15% restocking fee, and original shipping charges are non-refundable.
  • Warranty returns require authorization, the original sales receipt, and an explanation of the product issue.

Questions? Contact support@propondsupply.com or call (470) 354-1969.

Warranty

Warranty

  • Kasco Marine products are warranted to be free from defects in material and workmanship under normal use and service.
  • 2-year warranty: 1/2, 3/4, and 1HP Surface Aerators, J Series fountains, VFX fountains, AquatiClear™ Circulators, all 50Hz fountain, aerator, de-icer, and circulator models, LEDC11 Composite LED Light Kits, RGB LED Light Kits, Home Series cabinet and TeichAire compressor, and HydraForce™ Lift Station Agitators.
  • 3-year warranty: 1/2, 3/4, and 1HP De-icers, 2, 3, and 5HP VFX and Surface Aerator models, 2HP J Series models, LEDS19 Stainless Steel Light Kits, RGBW18 LED Light Kits, W25 LED Light Kits, CertiSafe™ Tank Mixers, and RobustAire™ TeichAire Compressors.
  • 5-year warranty: 3, 5, and 7.5HP J Series fountains and RGBW LED Light Kits.
  • 15-year warranty: SureSink™ Weighted Tubing for RobustAire™ and Home Series Diffused Aeration Systems.
  • Lifetime warranty: Diffuser assemblies for RobustAire™ and Home Series Diffused Aeration Systems, RobustAire™ Post Mount Cabinets, and RobustAire™ Small, Medium, and Large Cabinets with patented AireGuard Cabinet Technology.
  • Control panels are included in the warranty when applicable to the covered product.
  • Ropes, power cords, and propellers are excluded from standard defect coverage.
  • Customers should register their product with Kasco Marine for warranty purposes after purchase.
  • Warranty coverage may be void if the equipment is not properly maintained according to the owner’s manual, altered from its original condition, used without the required GFI-protected circuit or Kasco control panel, or damaged by unauthorized tampering.
  • Units under warranty may be sent to a Kasco authorized repair center for evaluation and repair, and all units must include the required Repair Contact Form.
  • Only complete motor assemblies will be accepted for warranty repair, and the power cord and all other original components must be returned with the motor as originally assembled.
  • Kasco Marine will return units repaired under warranty at their expense by ground freight within the continental United States, while expedited return shipping is the customer’s responsibility.

Questions? Contact support@propondsupply.com or call (470) 354-1969.

★Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)